| T130 Technical Specifications | ||
| Performance Statistics | ||
| Water Temp / Ambient Air / Relative Humidity | BTUs (British Thermal Units) | Coefficient of Performance Boost Mode [Eco Mode*] |
| 80/80/80 | 123,000 | 5.7 [10.8*] |
| 80/80/63 | 114,000 | 5.4 |
| 80/50/63 | 65,000 | 4.2 |
| Unit Specifications | ||
| Refrigerant | R32 | |
| Electrical Specifications | ||
| kW Input | 6.3 kW | |
| kW Output | 26.0 - 19.1 kW | |
| Voltage/Hz/Phase | 230V/60hz/1 | |
| Min Circuit Ampacity | 27.4 | |
| Max Fuse Size | 40 | |
| Water Flow | ||
| Max Flow (GPM) | 30/70 GPM | |
| Unit Dimensions | ||
| Installed | Shipping | |
| Weight (lbs) | 271 lbs | 315 lbs |
| Length x Width x Height (inches) | 46"x21"x47" | 47"x22"x54" |
| Technical Specifications Comparison | |||
| Model | T70 | T100 | T130 |
| BTUs (Water Temp/Ambient Air/Relative Humidity) | |||
| 80/80/80 | 63,000 | 108,000 | 123,000 |
| 80/80/63 | 60,000 | 104,000 | 114,000 |
| 80/50/63 | 26,500 | 47,500 | 65,000 |
| Coefficient of Performance (Water Temp/Ambient Air/Relative Humidity) | |||
| Boost Mode [Eco Mode*] | |||
| 80/80/80 | 5.4 [10.8*] | 5.0 [10.8*] | 5.7 [10.8*] |
| 80/80/63 | 5.2 | 4.8 | 5.4 |
| 80/50/63 | 4.0 | 4.2 | 4.2 |
| Unit Specifications | |||
| Refrigerant | R32 | R32 | R32 |
| Electrical Specifications | |||
| kW Input | 3.4 kW | 6.3 kW | 6.3 kW |
| kW Output | 18.5 – 7.8 kW | 31.7 – 13.9 kW | 26.0 – 19.1 kW |
| Voltage/Hz/Phase | 230V/60hz/1 | 230V/60hz/1 | 230V/60hz/1 |
| Min Circuit Ampacity | 13.1 | 27.3 | 27.4 |
| Max Fuse Size | 20 | 40 | 40 |
| Water Flow | |||
| Max Flow (GPM) | 20/60 GPM | 30/70 GPM | 30/70 GPM |
| Weight (lbs) | |||
| Installed | 139 lbs | 207 lbs | 271 lbs |
| Shipping | 158 lbs | 245 lbs | 315 lbs |
| Length x Width x Height (inches) | |||
| Installed | 43″x19″x28″ | 47″x21″x35″ | 46″x21″x47″ |
| Shipping | 44″x20″x35″ | 48″x22″x42″ | 47″x22″x54″ |