- 1-888-297-3826 (Call) / 239-482-0606 (Call)
- contact@aquathermheatpumps.com
- Mon - Fri: 8:00 AM - 4:00 PM
Model | AT75 | AT115 | AT130 | AT150 Heat & Cool | AT150 Heat Only |
---|---|---|---|---|---|
Cooling Performance | |||||
Cooling Condition (Water/Air/RH)* | N/A | N/A | N/A | 100/80/63 | N/A |
Rejected BTU/KW* | N/A | N/A | N/A | 75,000/22 | N/A |
EER (Energy Efficiency Ratio)* | N/A | N/A | N/A | 12 | N/A |
BTUs (Water Temp/Ambient Air/Relative Humidity) | |||||
80/80/80 | 74,000 | 112,000 | 134,000 | 126,000 | 143,000 |
80/80/63 | 70,000 | 106,000 | 125,000 | 120,000 | 134,000 |
80/50/63 | 49,000 | 74,000 | 84,000 | 82,000 | 90,000 |
Coefficient of Performance (Water Temp/Ambient Air/Relative Humidity) | |||||
80/80/80 | 5.6 | 5.6 | 5.7 | 5.6 | 6.5 |
80/80/63 | 5.4 | 5.4 | 5.6 | 5.3 | 6.1 |
80/50/63 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 |
Refrigerant | R410A | R410A | R410A | R410A | R410A |
Compressor | Reciprocating | Scroll | Scroll | Scroll | Scroll |
Heat Exchanger | Rifled Titanium – Tube in Tube | Thermolink – Tube In Shell | Thermolink – Tube In Shell | Thermolink – Tube In Shell | Thermolink – Tube In Shell |
Electrical | |||||
KW Input | 3.9 | 5.9 | 6.8 | 6.6 | 6.4 |
Voltage/Hz/Phase | 208-230V/60hz/1 | 208-230V/60hz/1 | 208-230V/60hz/1 | 208-230V/60hz/1 | 208-230V/60hz/1 |
Min Circuit Ampacity . | 31.65 | 41.8 | 41.8 | 42.06 | 42.06 |
Max Fuse Size | 50 | 60 | 60 | 60 | 60 |
Water Flow | |||||
Min/Max GPM | 20/45 | 30/70 | 30/70 | 30/70 | 30/70 |
Dimensions | |||||
Weight | 208 | 261 | 262 | 315 | 310 |
Length x Width x Height | 34 x 33.5 x 27.1 | 34 x 33.5 x 38.1 | 34 x 33.5 x 38.1 | 34 x 33.5 x 43.5 | 34 x 33.5 x 43.5 |